INFO: ERROR_BUS_RESET May Be Benign |
Q111837
The information in this article applies to:
- Microsoft Win32 Application Programming Interface (API), used with:
- the operating system: Microsoft Windows NT, versions 3.1, 3.5, 3.51, 4.0
- the operating system: Microsoft Windows 2000
SUMMARY
Tape API (application programming interface) functions may return an error code of ERROR_BUS_RESET when operating on SCSI tape devices. In many cases, you can ignore this error value and retry the operation. However, this error is fatal if received during a series of write operations because a tape drive cannot recover from a bus reset and continue writing.
MORE INFORMATION
When Windows NT starts it resets the SCSI bus. This bus reset is reported by the tape drive in response to the first operation after the reset.
The code fragment shown below in the Sample Code section could be used to check for ERROR_BUS_RESET and clear it. The same technique could be used for other informational errors, such as ERROR_MEDIA_CHANGED, that may not be relevant at application startup.
Sample Code
/* ** This is a code fragment only and will not compile and run as is. */ ... do { dwError = GetTapeStatus(hTape); } while (dwError == ERROR_BUS_RESET); ...
Additional query words:
Keywords : _IK kberrmsg kbAPI kbKernBase kbOSWin2000 kbTapeBackup kbDSupport kbGrpDSKernBase
Issue type : kbinfo
Technology : kbAudDeveloper kbWin32sSearch kbWin32API
Last Reviewed: October 27, 2000 |