Article ID: 110561
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
This article was previously published under Q110561
SYMPTOMS
The Turbo Modem Plus is not on the Windows NT Hardware Compatibility List and is not supported. However, the Turbo Modem Plus may be compatible when it is set up as a Hayes 14400 Ultra; except when it used as a Remote Access Service (RAS) Server, the modem may not auto-answer incoming calls.
WORKAROUND
A possible workaround to this problem is to disable error-checking in RAS, which is on by default.
To disable error-checking in RAS, do the following:
- From the Control Panel windows, choose the Networks icon.
- Select Remote Access Service, and then choose the Configure button.
- Select the modem, and then choose the Settings button.
- Clear the Enable Error Checking check box, and then choose the OK button.
If this does not correct the problem, contact the manufacturer of the Turbo Modem Plus.
Additional query words: prodnt
Keywords: kb3rdparty kbhardware KB110561