Article ID: 109544
Article Last Modified on 3/3/2005
APPLIES TO
- Microsoft OLE 2.01
- Microsoft OLE 4.0, when used with:
- Microsoft Windows NT 4.0
- Microsoft Windows NT 3.51 Service Pack 5
- Microsoft Windows 95
This article was previously published under Q109544
SYMPTOMS
When an OLE 2.0 container application calls IRunningObjectTable::IsRunning() on the moniker for a linked OLE 1.0 object, IsRunning() returns S_FALSE even if that OLE 1.0 object is already running.
CAUSE
OLE 1.0 objects do not register themselves in the running object table while they are running.
RESOLUTION
Calling IMoniker::IsRunning() on the moniker for a linked OLE 1.0 object correctly returns S_OK if the object is indeed running.
As noted in the OLE SDK version 2.01 documentation for IRunningObjectTable::IsRunning(), clients of a moniker should not call IRunningObjectTable::IsRunning() directly; instead, they should call IMoniker::IsRunning().
Additional query words: 2.01 3.50 4.00 irot