Microsoft KB Archive/108320: Difference between revisions
(importing KB archive) |
m (Text replacement - """ to """) |
||
Line 52: | Line 52: | ||
== MORE INFORMATION == | == MORE INFORMATION == | ||
On page 66 of the | On page 66 of the "SNA Device Interface Specification" (SNADIS), the last field provided in the Open(Station) request is incorrect.<br /> | ||
<br /> | <br /> | ||
The following entry | The following entry |
Latest revision as of 09:22, 20 July 2020
Article ID: 108320
Article Last Modified on 10/30/2003
APPLIES TO
- Microsoft SNA Server 2.0, when used with:
- Microsoft Windows NT 4.0
This article was previously published under Q108320
SUMMARY
The format of the Open(Station) request in the SNA Server 2.0 SNA Device Interface Specification (SNADIS) is documented incorrectly.
MORE INFORMATION
On page 66 of the "SNA Device Interface Specification" (SNADIS), the last field provided in the Open(Station) request is incorrect.
The following entry
dataru[s+44..s+45] Maximum BTU size to be used with this station
should be replaced by two fields: a link data field followed by a Maximum BTU size field. That is, the last line should become two lines as follows:
dataru[s+44..s+89] Copy of Link Data from Open(Link) request
dataru[s+90..s+91] Maximum BTU size to be used with this station
Additional query words: prodsna SNADIS BTU
Keywords: kbinfo kbother KB108320