ACC1x: GP Fault with PostMessage() to an ADK Application

Q105520



The information in this article applies to:


  • Microsoft Access Distribution Kit, version 1.1





SYMPTOMS

If you attempt to close a Microsoft Access Distribution Kit application by sending a WM_CLOSE message from another application using the PostMessage() Windows API function call, a general protection (GP) fault will occur.

The sample code


   x = PostMessage(hWnd, WM_CLOSE, 0, 0) 


will result in a GP fault when run in languages such as Microsoft Visual Basic, Microsoft Windows C, or Access Basic.



RESOLUTION

Use the WM_DESTROY window message instead of the WM_CLOSE message to close a run-time application. The following sample code demonstrates how to use the WM_DESTROY message:


   x = PostMessage(hWnd, WM_DESTROY, 0, 0) 



STATUS

Microsoft has confirmed this to be a problem in the Microsoft Access Distribution Kit version 1.1. This problem no longer occurs in the Microsoft Access Developer's Toolkit version 2.0.