Article ID: 105516
Article Last Modified on 5/6/2003
APPLIES TO
- Microsoft Access 1.0 Standard Edition
- Microsoft Access 1.1 Standard Edition
- Microsoft Access 2.0 Standard Edition
This article was previously published under Q105516
Novice: Requires knowledge of the user interface on single-user computers.
SUMMARY
This article describes how to print a conditional page header using an example that forces the page header (which contains the column header labels), to print on consecutive pages of the report if a data group spans more than one page.
The technique described in this article works for Microsoft Access versions 1.x and 2.0. However, an alternative method for version 2.0 is described in the Solutions sample application. See the "References" section of this article for a complete reference to this method.
MORE INFORMATION
Reports print group header information once per group, even if the group of data spans more than one page. In reports, a common layout is to place the grouping value in the group header along with the column labels. However, because this data is not repeated when a group spans more than one page, the column header labels are not repeated on the subsequent page(s).
To create conditional headers, you must create a new page before each group of data and set a flag from the group header to determine when the page header should print. Then, from the group footer, set the flag back so that the page header does not print at the beginning of the next group.
To create the conditional headers, follow these steps:
- Open the sample database NWIND.MDB.
- Create a new form called FlagForm. This form is used to store a global variable.
- Create one unbound control and set the following property:
Name: Flag
NOTE: In Microsoft Access version 1.x, the Name property is called the ControlName property. Create the following new macro, and name it Test:
Macro Name Condition Action ------------------------------------------------------------- SetFlag SetValue ShrinkPageH Forms![FlagForm]![Flag]=1 CancelEvent FlagOn SetValue FlagOff SetValue Test actions --------------------------------- SetFlag Item: Forms![FlagForm]![Flag] Expression: 1 CancelEvent: no arguments FlagOn Item: Forms![FlagForm]![Flag] Expression: 0 FlagOff Item: Forms![FlagForm]![Flag] Expression: 1
- Create a new blank report called PrintHeaders based on the Products table:
Set the following report header properties:
OnFormat: Test.SetFlag Height: 0
Set the following page header property:
OnFormat: Test.ShrinkPageH
Create a label in the page header section and set the following property:
Caption: Continued from Previous Page...
Create a grouping for the Category ID and set following properties:
Group Header: Yes Group Footer: Yes
Set the following group header properties:
OnFormat: Test.FlagOn ForceNewPage: Before Section
- Create a control in the group header section bound to the Category ID field.
- Create a text box control bound to the Product Name field in the detail section.
- Set the height property for the detail section to 2 inches. (This is to create groups of data that span more than one page.)
Set the following group footer property:
OnFormat: Test.FlagOff
- View the FlagForm form in Datasheet view.
- Preview the PrintHeaders report.
- Scroll through the report. Note the page headers for the groups.
REFERENCES
You can find information, instructions, and examples in the Solutions sample application (SOLUTION.MDB) included with Microsoft Access version 2.0. For more information about printing a conditional page header, open the SOLUTION.MDB database usually located in the ACCESS\SAMPAPPS directory. Select "Control what you print on reports" in the Select A Category Of Examples box, then "Repeat a group name at the top of a column or page" in the Select An Example box.
For more information about repeating group names, please see the following articles in the Microsoft Knowledge Base:
93927 ACC: Repeating Group Name at Top of New Column or Page (2.0)
Keywords: kbhowto kbusage KB105516