Article ID: 104732
Article Last Modified on 11/23/1999
APPLIES TO
- Microsoft MS-DOS 6.2 Standard Edition
- Microsoft MS-DOS 6.21 Standard Edition
- Microsoft MS-DOS 6.22 Standard Edition
- Microsoft Windows 3.1 Standard Edition
- Microsoft Windows 3.11 Standard Edition
- Microsoft Windows for Workgroups 3.1
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q104732
SYMPTOMS
Running Microsoft Diagnostics (MSD) under Windows or Window for Workgroups may result in one of the following error messages:
- This program has violated system integrity due to execution of an invalid instruction and will be terminated. -or-
- DoubleGuard Alarm #xx
A program has corrupted memory belonging to DoubleSpace. Further disk activity could result in the loss of some or all of the data on your drive. Therefore, DoubleGuard has halted your computer. For more information, see the README.TXT file.
RESOLUTION
To work around this problem, exit Windows or Windows for Workgroups before running MSD.
Additional query words: 6.22 6.20 DBLSPACE DBLGUARD DoubleGaurd #13 #14 #15 #16
Keywords: KB104732