Microsoft KB Archive/104594

From BetaArchive Wiki
Knowledge Base


Tandberg Firmware Versions Required for Windows NT

Article ID: 104594

Article Last Modified on 11/1/2006



APPLIES TO

  • Microsoft Windows NT Advanced Server 3.1
  • Microsoft Windows NT Workstation 3.1
  • Microsoft Windows NT Advanced Server 3.1
  • Microsoft Windows NT Workstation 3.5
  • Microsoft Windows NT Workstation 3.51
  • Microsoft Windows NT Workstation 4.0 Developer Edition
  • Microsoft Windows NT Server 3.5
  • Microsoft Windows NT Server 3.51
  • Microsoft Windows NT Server 4.0 Standard Edition



This article was previously published under Q104594

SYMPTOMS

There are certain firmware revisions required for Tandberg tape drives to run with the Tandberg tape driver supplied in Windows NT version 3.1. If the firmware revision is out of date, you may receive the following error message:

Fatal translation error on tape in Drive 1.

CAUSE

Tandberg tape drives require a firmware revisions to be able to work correctly with the backup program that comes with Windows NT.

RESOLUTION

Tandberg tape drives require the following revisions:

   Tandberg 3660     08:15
   Tandberg 3820     04:08
   Tandberg 4120     04:08
   Tandberg 4220     05:10
                



There are several ways to determine the firmware revision on a Tandberg tape drive. Some models have the revision printed on the back of the unit, others do not. If it is not printed on the outside of the tape unit, it can be found on an EPROM on the inside of the unit and may take the form

   966040 I04:12 92x7511
                



where 4:12 is the firmware revision number. If you do not know the firmware revision and cannot find out what it is, please contact the manufacturer. If the firmware revision is out of date, please contact the manufacturer and update the firmware.

The manufacturer can be contacted at one of the following:

   Tandberg Data in Norway
   Kjeisasvelen 172
   P.O. BOX 133 Kjelsas
   N-0411 OSLO, Norway
   Fax + 47 22 95 13 55
   Phone 47 22 18 90 90
   Email: vimo@tdata.no

   -or-

   Tandberg Data, INC.
   2649 Townsgate Rd.
   Suite 600
   Westlake Village, CA 91361
   Phone (800) 258-8285
   Fax (805) 495-4186
                




Additional query words: prodnt

Keywords: kbhardware KB104594