Microsoft KB Archive/104341

From BetaArchive Wiki
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

FIX: Arrange Button Increments Negative Window Coordinates

ID: Q104341

2.50 WINDOWS kbprg kbfixlist kbbuglist

The information in this article applies to:

  • Microsoft FoxPro for Windows, version 2.5

SYMPTOMS

Choosing the Arrange button in the Generate Screen dialog box increments negative screen positions by one pixel.

STATUS

Microsoft has confirmed this to be a problem in FoxPro 2.5 for Windows. This problem was corrected in FoxPro 2.5a for Windows.

MORE INFORMATION

Steps to Reproduce Problem

1. Issue the following command in the Command window in order to start

   the Screen Builder:

      CREATE SCREEN

2. From the Program menu, choose Generate. 3. Choose the Arrange button.

4. Drag the window definition for a screen panel to the left and up,

   until part of it is off the arrange area. At least one of the
   Horizontal or Vertical Position values should be negative.

5. Choose OK. 6. Choose the Arrange button again.

The negative position(s) are incremented by one pixel.

Additional reference words: FoxWin 2.50 buglist2.50 fixlist2.50a 2.50a KBCategory: kbprg kbfixlist kbbuglist KBSubcategory: FxtoolSbuilder

Keywords          : FxtoolSbuilder kbbuglist kbfixlist
Version           : 2.50
Platform          : WINDOWS
Solution Type     : kbfix

Last Reviewed: September 24, 1997