Latest revision as of 09:32, 20 July 2020
Article ID: 102975
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
This article was previously published under Q102975
UPS Service Entries
The Registry does not contain information for the UPS service until you check the Uninterruptible Power Supply Is Installed checkbox in the UPS dialog box and then chooses the OK button. Changes to settings should be made by using the UPS icon in Control Panel.
The UPS service will not start unless the UPS subkey is present in the Registry, all parameters are present in the Registry, and all values are within the correct range. If any of these elements are missing or in error, a message announces that the UPS service is not correctly configured. All corrections can be made using the UPS icon in Control Panel.
The UPS parameters remain in the Registry if you remove UPS. The path for the UPS subkey is the following:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\UPS BatteryLife REG_DWORD 2 to 720 minutes ------------------------------------------ Default: 2 (minutes)
Specifies the life of the UPS backup battery when fully charged.
CommandFile REG_EXPAND_SZ Filename -------------------------------------- Default: (empty)
Specifies the name of a command file to execute immediately before shutting down.
FirstMessageDelay REG_DWORD 0 to 120 seconds ------------------------------------------------ Default: 5 (seconds)
Specifies the number of seconds between initial power failure and the first message sent to the users. If power is restored within the FirstMessageDelay time, no message is sent, although the event is logged.
MessageInterval REG_DWORD 5 to 300 seconds ---------------------------------------------- Default: 120 (seconds)
Specifies the number of seconds between messages sent to users to inform them of power failure.
Options REG_DWORD Value ---------------------------
Defines the bit mask for messages related to options in the UPS dialog box, as the following:
Installed 0x00000001 PowerFailSignal 0x00000002 LowBatterySignal 0x00000004 CanTurnOff 0x00000008 PosSigOnPowerFail 0x00000010 PosSigOnLowBattery 0x00000020 PosSigShutOff 0x00000040 CommandFile 0x00000080 Port REG_SZ Port name ------------------------- Default: COM1
Specifies the name of the serial port the UPS is connected to.
RechargeRate REG_DWORD 1 to 250 minutes ------------------------------------------- Default: 100 (minutes)
Specifies the recharge rate of the UPS backup battery.
REFERENCES
Reference: "The Windows NT Resource Kit for Operating System Version 3.1".
Additional query words: prodnt
Keywords: kbother KB102975