Error message when you create a DAO workspace in a module in Access 2007: "Runtime error 3633"

Article ID: 928025

Article Last Modified on 10/15/2007



APPLIES TO

  • Microsoft Office Access 2007



SYMPTOMS

When you create a Data Access Objects (DAO) workspace in a module in Microsoft Office Access 2007, you receive error messages that resemble the following:

Runtime error 3633: Can not load DLL

User-defined type not defined

CAUSE

This issue occurs because the DAO workspace uses Remote Data Objects (RDO) to pass data directly to Open Database Connectivity (ODBC) drivers. RDOs are not included as part of 2007 Microsoft Office systems because they are not supported in 2007 Office programs.

MORE INFORMATION

For more information about this issue, click the following article number to view the article in the Microsoft Knowledge Base:

280513 Visual Basic 6.0 application generates Run-Time Error 3633 when it is run on a new computer



Additional query words: AC2007 ACC2007 Access2007