XADM: MMC Creates an RG Connector with Same Server as Both Local and Remote Bridgehead

Article ID: 252029

Article Last Modified on 2/26/2007



APPLIES TO

  • Microsoft Exchange 2000 Server Standard Edition



This article was previously published under Q252029


SYMPTOMS

When you create a Routing Group (RG) connector, you may unintentionally create a connector that has the same server configured as both the remote and local bridghead.

CAUSE

This behavior is caused by the feature of Microsoft Management Console (MMC) that allows you to change the properties of an object while property sheets are still open. This functionality can have unintended results.

RESOLUTION

Do not move a server into a new RG while you are creating a new RG connector. Also, make sure that you understand all implications before you decide to move a server into a new routing group.

STATUS

Microsoft has confirmed that this is a problem in Microsoft Exchange 2000 Server.