Microsoft KB Archive/174467

From BetaArchive Wiki
Knowledge Base


Two Separate Threads In WinSLI Critical Section Can Cause Hang

Article ID: 174467

Article Last Modified on 7/13/2004



APPLIES TO

  • Microsoft SNA Server 3.0 Service Pack 4, when used with:
    • Microsoft Windows NT 4.0
  • Microsoft SNA Server 4.0, when used with:
    • Microsoft Windows NT 4.0



This article was previously published under Q174467


SYMPTOMS

Two separate threads from an SLI application appear to gain access to the SLI critical section, coinciding with an application's SLI call that hangs and never completes. This problem was observed with a Win32 SLI application which supported over 50 different threads, each calling the SLI interface. At times, an SLI call would hang and fail to complete.

CAUSE

The SNA Server Winsli32.dll was not behaving correctly.

STATUS

Microsoft has confirmed this to be a problem in SNA Server version 3.0 and 3.0sp1. This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K



Additional query words: critical section hang thread

Keywords: kbbug kbfix kbnetwork KB174467