Microsoft KB Archive/172434

From BetaArchive Wiki
Knowledge Base


Article ID: 172434

Article Last Modified on 7/14/2004



APPLIES TO

  • Microsoft SNA Server 3.0 Service Pack 4
  • Microsoft SNA Server 4.0



This article was previously published under Q172434


SYMPTOMS

In SNA Server Manager, the 802.2 DLC tab of the DLC Connection Properties dialog box reports incorrect values for T1 and Ti timer ticks. The drop-down list box should report the following:

   Ticks    T1       T2      Ti
   ------------------------------
     1    200 ms     40 ms    1 s
     2    400 ms     80 ms    2 s
     3    600 ms    120 ms    3 s
     4    800 ms    160 ms    4 s
     5      1 s     200 ms    5 s
     6      1 s     400 ms    5 s
     7      2 s     800 ms   10 s
     8      3 s    1200 ms   15 s
     9      4 s    1600 ms   20 s
    10      5 s    2000 ms   25 s
                

Instead of that, the following is reported:

   Ticks    T1       T2      Ti
   ------------------------------
      1    200 ms    40 ms    1 s
      2    400 ms    80 ms    2 s
      3    600 ms    120 ms   3 s
      4    800 ms    160 ms   4 s
      5      1 s    200 ms    5 s
      6      2 s    400 ms   10 s
      7      3 s    800 ms   15 s
      8      4 s   1200 ms   20 s
      9      5 s   1600 ms   25 s
      0            2000 ms   30 s
                

If an SNA Server administrator wanted to set the T1 timer to 5s, he or she would select 9 ticks. This will be interpreted as 4s by the DLC layer, which is not the administrator's expectation. Also, for T2 and Ti, the Ticks value 10 appears as 0; the leading digit (1) is truncated.

CAUSE

This was due to a mismatch on the table where timer tick values were associated with a text string indicating the corresponding amount of time.

WORKAROUND

To work around this problem, do one of the following:

  • Use the Snacfg.exe command line tool


-OR-

  • Set (tick + 1) for T1 and Ti ticks greater than 5 when using SNA Explorer.


STATUS

Microsoft has confirmed this to be a problem in SNA Server versions 3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


MORE INFORMATION

With the fix applied, the table is updated so the text strings now indicate the real amount of time for each of the 10 T1, T2, and Ti timer Ticks, as shown on the first table above.

Keywords: kbbug kbfix kbnetwork kbui KB172434