Article ID: 171614
Article Last Modified on 6/28/2004
APPLIES TO
- Microsoft SNA Server 3.0 Service Pack 4
- Microsoft SNA Server 4.0
This article was previously published under Q171614
SYMPTOMS
The new LINKCFG.EXE program used to support command-line installation of link services was not properly saving registry entries when installing DCA SDLC or DCA X.25 link services.
Using identical configuration parameters to configure from both manager and linkcfg.exe resulted in these differences in the registry:
Manager 47286: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\DCASYNC\ Parameters\ExtraParameters Data1LS DCAX251 47335: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\DCAX251\ Parameters\ExtraParameters DeviceName DCADL$03 47348: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\DCAX251\ Parameters\ExtraParameters OSVCRng 0048-0050 Linkcfg 47286: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\DCASYNC\ Parameters\ExtraParameters Data1LS 47335: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\DCAX251\ Parameters\ExtraParameters DeviceName 47348: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\DCAX251\ Parameters\ExtraParameters OSVCRng
CAUSE
The Device Parameter Strings were overwritten by the un-initialized configuration buffer.
STATUS
Microsoft has confirmed this to be a problem in SNA Server, versions 3.0 and 3.0 SP1. This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: linkcfg registry DCA ISCA
Keywords: kbbug kbfix KB171614