Article ID: 107746
Article Last Modified on 9/30/2003
APPLIES TO
- Microsoft LAN Manager 2.2 Standard Edition
This article was previously published under Q107746
SYMPTOMS
Page faults occurred in WINSOCK.DLL @ 0001:8AB9 if VXConnect software was used to connect to Data General with MediTech emulation.
CAUSE
Memory in WINSOCK.DLL was being swapped after it was allocated for the protected mode buffer that contains the data transferred to and from the system.
RESOLUTION
Code was changed so that buffers now are allocated as movable and memory is then immediately locked so it cannot be swapped.
STATUS
This fix is in the LAN Manager 2.2 patch.
Additional query words: 2.20 2.2 winsock trap fault terminal sockets
Keywords: KB107746