Article ID: 103154
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Workstation 4.0 Developer Edition
- Microsoft Windows NT Server 3.5
- Microsoft Windows NT Server 3.51
- Microsoft Windows NT Server 4.0 Standard Edition
This article was previously published under Q103154
The following error may occur in the event log when a logical link connection (LLC) entity receives an invalid data unit:
FRMR is the Frame Reject frame sent by the NetBEUI Frames (NBF) LLC layer when one of the following conditions causes a data unit to become invalid:
- Invalid sequence number
- Invalid presence of an information field
- Maximum allowable length for an LLC data unit is exceeded
These errors cannot be corrected by retransmission. In response to the FRMR frame, the workstation sends a Disconnect (DISC) command to terminate the link connection. The workstation may then reestablish the connection.
Additional query words: prodnt Event:9011
Keywords: kbnetwork KB103154