X400: Downstream Users Receive Multiple Copies of Messages
PSS ID Number: Q100829 Article last modified on 12-20-1993
3.00 MS-DOS
The information in this article applies to: |
- Microsoft Mail Gateway to X.400, version 3.0 |
SYMPTOMS
Downstream postoffice mail recipients of Microsoft Mail Gateway to X.400 may receive multiple copies of the same mail message.
CAUSE
This problem occurs only when the message is generated by certain foreign X.400 systems and does not occur when backboning MS Mail postoffices through X.400. In the following text, P1 and P2 apply to X.400 messages only. When an X.400 message comes into the X.400 gateway with one recipient in P1 (or one recipient with P1 responsibility bit set to TRUE and the rest FALSE) and multiple P2 recipients AND those recipients are located at a downstream postoffice (NOT the gateway postoffice), the X.400 gateway formats the message using ALL the P2 recipients for delivery. The result is that one mail message is created and addressed to the same recipient, for as many recipients listed in the P2.
RESOLUTION
This problem has been corrected in version 3.2 of Microsoft Mail Gateway to X.400.
Additional reference words: 3.00 X400
Copyright Microsoft Corporation 1993.